| Type | ME280 |
| Power Rate | Three phases: 380: 3.7 ~ 90kW (P -type machine) |
| Frequency Instruction | Digital settings: 0.01Hz; Simulation Settings: The highest frequency × 0.025% |
| Control Method | V/F Control |
| Torque Improvement | Automatic torque increase; manual torque increases by 0.1%~ 30.0% |
| V/f Curve | Line, multi -point, square V/F, complete V/F separation, incomplete V/f separation |
| Plus And Slowing Curve | Pass or S -curve acceleration method; four kinds of acceleration time, acceleration time range of 0.0 ~ 6500.0s |
| DC Brake | DC brake starting frequency: 0.00Hz ~ maximum frequency; braking time: 0.0S ~ 36.0s; brake action current value: 0.0%~ 100.0% |
| Dot Control | Diminal frequency range: 0.00Hz ~ 50.00Hz; click to increase the deceleration 0.0s ~ 6500.0s |
| Simple PLC, Multi -Segment Speed Operation | Realize up to 16 segments by built -in PLC or control terminals |
| Built -In PID | Convenient to achieve process control closed -loop control system |
| AVR | When the power grid voltage changes, it can automatically keep the output voltage constant |
| Excess Over Pressure Control Speed Control | The current voltage is automatically limited during operation to prevent frequent over -flow overvoltage failure |
| Quick Current Limit Function | Maximize the overcurrent failure, protect the frequency converter normally running |
| Current Limitation And Control | Automatic limit of current during operation to prevent frequent overcurrent failures |
| Stop | During the instantaneous power outages, the energy compensation voltage is reduced through the load, and the inverter continues to run in a short period of time |
| Fast Current Limit | Avoid frequent frequent transition faults |